Neodisher MediKlar
for the rinse afterwardsFor fast and stain-free drying of machine reprocessing of surgical instruments incl. ophthalmic instruments, anaesthetic utensils, containers and implants. Significantly shortens the drying time.
Field of application:
- - Rinsing of medical devices such as surgical instruments incl. ophthalmic instruments, anaesthetic utensils, instrument containers, flexible endoscopes and implants and implants as well as baby bottles in washer-disinfectors.
Performance spectrum:
- - Very good wetting properties - for quick and for fast and streak-free drying of the goods to be treated
- - Sterile packaging made of paper/foil becomes by contact with medical devices that have been treated with neodisher MediKlar, not adversely affected
- - Accessories of anaesthesia equipment made of polysulphone (PSU) and polyphenylene- (PPSU) such as connectors for laryngeal masks laryngeal masks, valves, adaptors and parts of instrument and parts of instrument container lids can contact with rinsing agents may form stress cracks due to the manufacturing process. They must be pre-tested for suitability.
- - When neodisher MediKlar is used as directed neodisher MediKlar the biocompatibility of the treated of the treated instruments is not affected (Biological evaluation of medical devices according to EN ISO 10993-1).
Special properties:
- - Significantly reduces drying time
- - Reduces the time and energy required in mechanical reprocessing
Application and dosage:
neodisher MediKlar is used in the final rinse in washer-disinfectors.
in washer-disinfectors and disinfectors
washer-disinfectors. The dosage depends on the wash ware and the
and the water quality and is 0.3 - 1.0 ml
is 0.3 - 1.0 ml/l. The dosage is added to the
the final rinse water.
Use suitable dosing devices for dosing.
be used for dosing.
To avoid water stains, we recommend the use of
use of demineralised water in the final rinse
final rinse is recommended.
General instructions for use:
- - For professional use only.
- - Do not mix with other products.
- - Before product change Dosing system system including suction hoses with water with water.
- - Follow the operating instructions of the instructions of the detergent and disinfectant manufacturers must be observed.
- - Reprocessing must be carried out in accordance with medical device legislation and the applicable regulations with suitable
- validated procedures.
- - Please observe the reprocessing recommendations of the medical device manufacturer in accordance with the requirements of DIN EN ISO 17664.